J
Specifications
Ratings
Rated voltage
125 VAC
250 VAC
7A
7A
Resistive load
J
Note:
The ratings values apply under the following test conditions:
Ambient temperature: 20 ± 2 ° C
Ambient humidity: 65 ± 5%
Operating frequency: 30 operations/min
Switching Capacity per Load (Reference Values)
Voltage
Non-inductive load
Inductive load
Resistive load
Lamp load
Inductive load
Motor load
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
NC
7A
7A
7A
7A
5A
0.4 A
0.2 A
NO
NC
1.5 A
1.5 A
1.5 A
1.5 A
1.5 A
0.4 A
0.2 A
NO
0.7 A
0.7 A
0.7 A
0.7 A
0.7 A
0.4 A
0.2 A
NC
4A
4A
3A
3A
3A
0.03 A
0.02 A
NO
NC
2.5 A
2.5 A
2.5 A
2.5 A
2.5 A
0.03 A
0.02 A
NO
1.3 A
1.3 A
1.3 A
1.3 A
1.3 A
0.03 A
0.02 A
Note:
1. The above values are for the steady-state current.
2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Characteristics
Operating speed
Operating frequency
Insulation resistance
Contact resistance (initial value)
Dielectric strength
Vibration resistance (see note 2)
Shock resistance (see note 2, 3)
Durability (see note 4)
Degree of protection
Degree of protection against
electric shock
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating humidity
Weight
0.05 mm to 1 m/s (pin plunger models)
Mechanical: 400 operations/min max.
Electrical: 30 operations/min max.
100 M ? min. (at 500 VDC)
15 m ? max.
600 VAC, 50/60 Hz for 1 min between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part and
between current-carrying metal part and ground.
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s 2 {approx. 100G} max.
Malfunction: 200 m/s 2 {approx. 20G} max. (pin plunger models)
Mechanical: 10,000,000 operations min. (60 operations/min)
Electrical: 50,000 operations min. (30 operations/min)
IEC IP40
Class I
175
–10 ° C to 80 ° C (at ambient humidity of 60% max.) (with no icing)
85% max. (for 5 ° C to 35 ° C)
Approx. 1 g (pin plunger models)
Note:
1. The data given above are initial values.
2. Malfunction: 1 ms max.
3. For the pin plunger models, the values are at the free position and total travel position. For the lever models, they are at the total
travel position.
4. For testing conditions, consult your OMRON sales representative.
204